{"id":6771,"date":"2025-11-19T13:02:52","date_gmt":"2025-11-19T12:02:52","guid":{"rendered":"https:\/\/www.aq-tech.fr\/fr\/?page_id=6771"},"modified":"2026-03-21T06:37:05","modified_gmt":"2026-03-21T05:37:05","slug":"capteurs-textiles-integres","status":"publish","type":"page","link":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/","title":{"rendered":"Capteurs textiles int\u00e9gr\u00e9s"},"content":{"rendered":"<div id=\"Poles\">\r\n\r\n  <!-- BLOC 1 : TITRE -->\r\n  <div id=\"Bloc1Titre\" class=\"TroisQuart\">\r\n    <img decoding=\"async\" class=\"imagetitre\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Banniere-Capteur-Smart-Textile.webp\" alt=\"Capteurs textiles int\u00e9gr\u00e9s AQ-Tech \u2014 ECG, EMG, IMU\" \/>\r\n    <div class=\"video-overlay\"><\/div>\r\n    <div id=\"Bloc1TitreContent\">\r\n      <div class=\"container\">\r\n        <img decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Droite.webp\" alt=\"fleche\" class=\"animate-slide-up\" \/>\r\n        <h1 class=\"\">Capteurs Textiles Int\u00e9gr\u00e9s<\/h1>\r\n        <h1 class=\"animate-slide-up\">ECG, EMG, IMU &amp; Mesure Physiologique dans le V\u00eatement<\/h1>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- FIL D'ARIANE -->\r\n  <nav id=\"Ariane\" class=\"breadcrumb-container BlocGris20\">\r\n    <div class=\"container\">\r\n      <a href=\"\/fr\/\">Accueil<\/a>\r\n      <span class=\"breadcrumb-separator\">\u203a<\/span>\r\n      <a href=\"\/fr\/poles\/smart-textile\/\">P\u00f4le Smart Textile<\/a>\r\n      <span class=\"breadcrumb-separator\">\u203a<\/span>\r\n      <span class=\"breadcrumb-current\">Capteurs Textiles Int\u00e9gr\u00e9s<\/span>\r\n    <\/div>\r\n  <\/nav>\r\n\r\n  <!-- BLOC 2 : INTRO -->\r\n  <div id=\"Bloc2Intro\" class=\"ImageTexte TroisQuart BlocGris20\">\r\n    <div class=\"container relative\">\r\n      <img decoding=\"async\" class=\"absolute\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" \/>\r\n      <div class=\"ImageTexteBlocImgContainer\" style=\"margin-top: 50px\">\r\n        <img decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Integration-Electrode.webp\" alt=\"Capteurs textiles int\u00e9gr\u00e9s \u2014 int\u00e9gration \u00e9lectrode ECG dans textile AQ-Tech\" \/>\r\n      <\/div>\r\n      <div id=\"Bloc2AccueilTextContainer\" class=\"ImageTexteBlocTextContainer animate-slide-right\">\r\n        <h2>Des architectures de capteurs textiles robustes, pr\u00e9cises et industrialisables.<\/h2>\r\n        <div class=\"titre-underline\"><\/div>\r\n        <p>\r\n          Les capteurs rigides ont leurs limites d\u00e8s qu&rsquo;il s&rsquo;agit de mesurer le corps en mouvement. AQ-Tech con\u00e7oit des <strong>capteurs textiles int\u00e9gr\u00e9s<\/strong> capables de mesurer des signaux physiologiques \u2014 ECG, EMG, respiration, temp\u00e9rature \u2014 et des param\u00e8tres m\u00e9caniques \u2014 mouvement, flexion, pression, vibration \u2014 avec une pr\u00e9cision compatible \u00e0 une utilisation clinique ou industrielle.\r\n        <\/p>\r\n        <p>\r\n          Notre approche repose sur la combinaison de trois disciplines ma\u00eetris\u00e9es en interne : le <a href=\"\/fr\/expertises\/textile-technique\/\" class=\"lientexte\">textile technique<\/a> pour les mat\u00e9riaux conducteurs et le confort, l&rsquo;<a href=\"\/fr\/expertises\/electronique-logiciel\/\" class=\"lientexte\">\u00e9lectronique embarqu\u00e9e<\/a> pour les modules de mesure basse consommation, et le traitement du signal pour la fiabilit\u00e9 en conditions r\u00e9elles. Chaque architecture est con\u00e7ue d\u00e8s le d\u00e9part pour la lavabilit\u00e9, la durabilit\u00e9 et l&rsquo;industrialisabilit\u00e9.\r\n        <\/p>\r\n        <p>\r\n          Nous travaillons avec les acteurs du sport de performance, du <a href=\"\/fr\/secteurs\/medical-bien-etre\/\" class=\"lientexte\">m\u00e9dical<\/a> (DM classe I et II), de l&rsquo;<a href=\"\/fr\/secteurs\/industrie\/\" class=\"lientexte\">industrie<\/a> (ergonomie, EPI) et de la recherche. Du premier prototype fonctionnel \u00e0 la validation clinique, la m\u00eame \u00e9quipe suit le projet \u2014 sans rupture de connaissance entre les phases.\r\n        <\/p>\r\n        <div class=\"btn-orange liensection\">\r\n          <a href=\"\/fr\/contact\/\">+ Discutons de vos capteurs textiles<\/a>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- BLOC 3 : TYPES DE CAPTEURS -->\r\n  <div id=\"Bloc3Detail\">\r\n    <div class=\"TitreCentre container\">\r\n      <h2>Nos capteurs textiles int\u00e9gr\u00e9s<\/h2>\r\n      <div class=\"titre-underline\"><\/div>\r\n      <p class=\"black\">\r\n        <span class=\"bold\">Une expertise unique combinant mat\u00e9riaux conducteurs, \u00e9lectronique embarqu\u00e9e et architecture textile avanc\u00e9e \u2014 pour des solutions fiables du prototype \u00e0 la pr\u00e9-s\u00e9rie.<\/span>\r\n      <\/p>\r\n    <\/div>\r\n    <div class=\"container\">\r\n\r\n      <!-- \u00c9lectrodes textiles -->\r\n      <div class=\"bloc_expertise expertise_debut animate-slide-left\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Droite.webp\" alt=\"\" class=\"expertise_fleche\" \/>\r\n        <div class=\"bloc_expertise_img_container\">\r\n          <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Integration-Electrode.webp\" alt=\"\u00c9lectrode textile ECG EMG lavable AQ-Tech\" \/>\r\n        <\/div>\r\n        <div class=\"bloc_expertise_text_container\">\r\n          <h3>\u00c9lectrodes textiles<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p class=\"bold black\">Des \u00e9lectrodes souples, robustes et stables pour la mesure des signaux physiologiques.<\/p>\r\n          <p class=\"black\">Les \u00e9lectrodes textiles remplacent les \u00e9lectrodes gel classiques en offrant un contact continu, confortable et lavable. Nous les d\u00e9veloppons pour l&rsquo;ECG (suivi cardiaque), l&rsquo;EMG (mesure musculaire) et la conductance cutan\u00e9e, en s\u00e9lectionnant les mat\u00e9riaux conducteurs les mieux adapt\u00e9s \u00e0 chaque usage \u2014 tissus argent\u00e9s, encres conductrices, broderie ou tricot.<\/p>\r\n          <ul class=\"black\">\r\n            <li>+ Technologies : tissage, tricot, broderie, impression conductrice<\/li>\r\n            <li>+ Imp\u00e9dance optimis\u00e9e &amp; faible bruit<\/li>\r\n            <li>+ R\u00e9sistance \u00e0 la sueur, compression et d\u00e9formation<\/li>\r\n            <li>+ Connectique textile &amp; lavabilit\u00e9 garantie<\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <!-- Respiration -->\r\n      <div class=\"bloc_expertise expertise_gauche animate-slide-right\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" alt=\"\" class=\"expertise_fleche\" \/>\r\n        <div class=\"bloc_expertise_img_container\">\r\n          <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Mesure-Respiration.webp\" alt=\"Capteur respiration textile \u2014 mesure thoracique et abdominale AQ-Tech\" \/>\r\n        <\/div>\r\n        <div class=\"bloc_expertise_text_container\">\r\n          <h3>Mesure de la respiration<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p class=\"bold black\">D\u00e9tection thoracique, amplitude respiratoire et fr\u00e9quence en temps r\u00e9el.<\/p>\r\n          <p class=\"black\">La mesure respiratoire dans un textile est l&rsquo;une des applications les plus demand\u00e9es en sport de performance et en monitoring m\u00e9dical. Nos architectures stretch-sensing multi-zones permettent de mesurer simultan\u00e9ment les mouvements thoraciques et abdominaux avec une pr\u00e9cision stable, m\u00eame lors d&rsquo;efforts intenses ou de transitions posturales.<\/p>\r\n          <ul class=\"black\">\r\n            <li>+ Pl\u00e9thysmographie par boucle d&rsquo;inductance (RIP)<\/li>\r\n            <li>+ Fibres pi\u00e9zor\u00e9sistives ou capacitives<\/li>\r\n            <li>+ Architectures stretch-sensing multi-zones<\/li>\r\n            <li>+ Mesure thorax + abdomen<\/li>\r\n            <li>+ Pr\u00e9cision stable m\u00eame lors de mouvements intenses<\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <!-- Temp\u00e9rature -->\r\n      <div class=\"bloc_expertise expertise_droite animate-slide-left\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" alt=\"\" class=\"expertise_fleche\" \/>\r\n        <div class=\"bloc_expertise_img_container\">\r\n          <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/body-temperature-sensor.webp\" alt=\"Capteur de temp\u00e9rature cutan\u00e9e textile AQ-Tech\" \/>\r\n        <\/div>\r\n        <div class=\"bloc_expertise_text_container\">\r\n          <h3>Mesure de la temp\u00e9rature<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p class=\"bold black\">Suivi thermique cutan\u00e9 ou ambiant via des architectures textiles d\u00e9di\u00e9es.<\/p>\r\n          <p class=\"black\">La mesure de la temp\u00e9rature cutan\u00e9e dans un v\u00eatement est particuli\u00e8rement utile pour le monitoring m\u00e9dical (d\u00e9tection fi\u00e8vre, suivi patient), la r\u00e9cup\u00e9ration sportive et les dispositifs de thermoth\u00e9rapie active. Nos architectures utilisent des fils thermosensibles ou des mini-sondes encapsul\u00e9es, toutes valid\u00e9es pour la lavabilit\u00e9 et les contraintes m\u00e9caniques du v\u00eatement.<\/p>\r\n          <ul class=\"black\">\r\n            <li>+ Fils ou encres conductrices thermosensibles<\/li>\r\n            <li>+ Mini sondes thermom\u00e9triques souples<\/li>\r\n            <li>+ Compensation thermique firmware<\/li>\r\n            <li>+ Architectures lavables et r\u00e9sistantes<\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <!-- IMU -->\r\n      <div class=\"bloc_expertise expertise_gauche animate-slide-right\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" alt=\"\" class=\"expertise_fleche\" \/>\r\n        <div class=\"bloc_expertise_img_container\">\r\n          <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Mesure_IMU.webp\" alt=\"Capteurs IMU int\u00e9gr\u00e9s textile \u2014 suivi mouvement et posture AQ-Tech\" \/>\r\n        <\/div>\r\n        <div class=\"bloc_expertise_text_container\">\r\n          <h3>Capteurs de mouvement (IMU)<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p class=\"bold black\">Suivi du geste, de la posture ou de la cin\u00e9matique articulaire.<\/p>\r\n          <p class=\"black\">Les capteurs IMU int\u00e9gr\u00e9s dans le v\u00eatement permettent une analyse biom\u00e9canique pr\u00e9cise sans marqueurs ni cam\u00e9ra. Utilis\u00e9s pour la pr\u00e9vention des TMS en industrie, l&rsquo;analyse du geste sportif ou le suivi postural m\u00e9dical, ils s&rsquo;associent \u00e0 notre traitement du signal embarqu\u00e9 pour fournir des donn\u00e9es directement exploitables dans l&rsquo;application cliente.<\/p>\r\n          <ul class=\"black\">\r\n            <li>+ IMU MEMS segmentaire : acc\u00e9l\u00e9ro \/ gyro \/ magn\u00e9to<\/li>\r\n            <li>+ Synchronisation multi-capteurs pour v\u00eatements instrument\u00e9s<\/li>\r\n            <li>+ Positionnement biom\u00e9canique pr\u00e9cis<\/li>\r\n            <li>+ Traitement du signal embarqu\u00e9 ou dans application<\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <!-- Vibration & impact -->\r\n      <div class=\"bloc_expertise expertise_droite animate-slide-left\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" alt=\"\" class=\"expertise_fleche\" \/>\r\n        <div class=\"bloc_expertise_img_container\">\r\n          <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Mesure-Mouvement.webp\" alt=\"Capteurs de vibration et impact textiles AQ-Tech\" \/>\r\n        <\/div>\r\n        <div class=\"bloc_expertise_text_container\">\r\n          <h3>Capteurs de vibration et impact<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p class=\"bold black\">D\u00e9tection de micro-impacts, tremblements et signatures vibratoires.<\/p>\r\n          <p class=\"black\">La d\u00e9tection de vibrations et d&rsquo;impacts dans un v\u00eatement ou un EPI ouvre des applications sp\u00e9cifiques : analyse musculaire (tremor, fatigue), \u00e9valuation de la fatigue en sport, d\u00e9clenchement d&rsquo;airbag ou v\u00eatement de protection active. Nos architectures combinent acc\u00e9l\u00e9rom\u00e8tres MEMS haute sensibilit\u00e9 et fibres vibratoires souples selon la plage de fr\u00e9quences et la g\u00e9om\u00e9trie cibles.<\/p>\r\n          <ul class=\"black\">\r\n            <li>+ Acc\u00e9l\u00e9rom\u00e8tres haute sensibilit\u00e9<\/li>\r\n            <li>+ Fibres vibratoires souples<\/li>\r\n            <li>+ Analyse musculaire (tremor, fatigue)<\/li>\r\n            <li>+ D\u00e9tection d&rsquo;impact pour sport &amp; EPI<\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <!-- Flexion & \u00e9longation -->\r\n      <div class=\"bloc_expertise expertise_gauche animate-slide-right\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" alt=\"\" class=\"expertise_fleche\" \/>\r\n        <div class=\"bloc_expertise_img_container\">\r\n          <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Capteur-Elongation.webp\" alt=\"Capteurs de flexion \u00e9longation d\u00e9formation textile AQ-Tech\" \/>\r\n        <\/div>\r\n        <div class=\"bloc_expertise_text_container\">\r\n          <h3>Capteurs de flexion, \u00e9longation &amp; d\u00e9formation<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p class=\"bold black\">Mesure des mouvements articul\u00e9s et des d\u00e9formations textiles.<\/p>\r\n          <p class=\"black\">Les capteurs de flexion et d&rsquo;\u00e9longation int\u00e9gr\u00e9s dans un v\u00eatement permettent de mesurer les angles articulaires (genou, coude, colonne) et les d\u00e9formations de la structure textile. Utilis\u00e9s en r\u00e9\u00e9ducation, analyse sportive ou contr\u00f4le d&rsquo;EPI, ces capteurs sont adapt\u00e9s aux contraintes d&rsquo;\u00e9tirement r\u00e9p\u00e9t\u00e9 en conditions r\u00e9elles, avec une d\u00e9rive de signal ma\u00eetris\u00e9e sur la dur\u00e9e.<\/p>\r\n          <ul class=\"black\">\r\n            <li>+ Fibres pi\u00e9zor\u00e9sistives extensibles<\/li>\r\n            <li>+ Impressions stretch-sensing<\/li>\r\n            <li>+ Analyse du geste sportif ou professionnel<\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n\r\n      <!-- Autres mesures bio-physiques -->\r\n      <div class=\"bloc_expertise expertise_droite expertise_fin animate-slide-left\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" alt=\"\" class=\"expertise_fleche\" \/>\r\n        <div class=\"bloc_expertise_img_container\">\r\n          <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Capteurs\/Produit-Textile.webp\" alt=\"Autres capteurs biophysiques textiles AQ-Tech \u2014 GSR, pression, hydratation\" \/>\r\n        <\/div>\r\n        <div class=\"bloc_expertise_text_container\">\r\n          <h3>Autres mesures bio-physiques<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p class=\"bold black\">Des capteurs avanc\u00e9s pour des mesures complexes sur le corps humain.<\/p>\r\n          <p class=\"black\">Certains projets n\u00e9cessitent des mesures moins conventionnelles : taux d&rsquo;hydratation cutan\u00e9e, r\u00e9ponse \u00e9lectrodermale (GSR \u2014 stress, vigilance, confort thermique) ou pression musculaire locale. Nous d\u00e9veloppons ces architectures sp\u00e9cifiques en adaptant mat\u00e9riaux et proc\u00e9d\u00e9s d&rsquo;int\u00e9gration \u00e0 chaque cas d&rsquo;usage, avec les m\u00eames exigences de lavabilit\u00e9 et de robustesse.<\/p>\r\n          <ul class=\"black\">\r\n            <li>+ Humidit\u00e9 \/ sudation (capacitif &amp; r\u00e9sistif)<\/li>\r\n            <li>+ GSR \/ EDA (conduction cutan\u00e9e)<\/li>\r\n            <li>+ Pression \/ compression musculaire<\/li>\r\n          <\/ul>\r\n        <\/div>\r\n      <\/div>\r\n\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- BLOC 4 : MOYENS TECHNIQUES -->\r\n  <div id=\"Bloc4Methdologie\" class=\"ImageTexte Demi BlocGris20\">\r\n    <div class=\"container relative\">\r\n      <img loading=\"lazy\" decoding=\"async\" class=\"absolute\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" \/>\r\n      <div class=\"Image4Cartes\">\r\n        <div class=\"icone-pilier\">\r\n          <i class=\"fa-solid fa-atom\"><\/i>\r\n          <h4>Mat\u00e9riaux conducteurs<\/h4>\r\n          <p>\u00c9lectrodes, encres conductrices, fils et fibres capteurs s\u00e9lectionn\u00e9s pour chaque usage.<\/p>\r\n        <\/div>\r\n        <div class=\"icone-pilier\">\r\n          <i class=\"fa-solid fa-flask\"><\/i>\r\n          <h4>Mesure &amp; calibration<\/h4>\r\n          <p>Bancs ECG\/EMG, calibration IMU, pression &amp; flexion \u2014 validation interne syst\u00e9matique.<\/p>\r\n        <\/div>\r\n        <div class=\"icone-pilier\">\r\n          <i class=\"fa-solid fa-layer-group\"><\/i>\r\n          <h4>Int\u00e9gration textile<\/h4>\r\n          <p>Couture, laminage, surmoulage silicone, assemblage multi-mat\u00e9riaux pour chaque architecture.<\/p>\r\n        <\/div>\r\n        <div class=\"icone-pilier\">\r\n          <i class=\"fa-solid fa-microchip\"><\/i>\r\n          <h4>\u00c9lectronique embarqu\u00e9e<\/h4>\r\n          <p>Modules basse consommation, ADC haute pr\u00e9cision, firmware et traitement du signal.<\/p>\r\n        <\/div>\r\n      <\/div>\r\n      <div id=\"ImageTexteBlocTextContainer\" class=\"ImageTexteBlocTextContainer animate-slide-right\">\r\n        <h2>Nos moyens d\u00e9di\u00e9s aux capteurs textiles<\/h2>\r\n        <div class=\"titre-underline\"><\/div>\r\n        <p>\r\n          AQ-Tech dispose d&rsquo;un laboratoire complet pour concevoir, tester et valider les capteurs textiles : bancs de mesure physiologique (ECG, EMG, respiration), outils de broderie technique et d&rsquo;impression conductrice, calibration IMU, tests de pression et \u00e9quipements de mesure avanc\u00e9e. Un environnement unique pour d\u00e9velopper des <strong>capteurs textiles lavables<\/strong> industrialisables \u2014 de la preuve de concept \u00e0 la pr\u00e9-s\u00e9rie certifi\u00e9e.\r\n        <\/p>\r\n        <div class=\"btn-orange liensection\">\r\n          <a href=\"\/fr\/contact\/\">+ Discutons de vos capteurs textiles<\/a>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- BLOC SUCCESS STORIES -->\r\n  <div id=\"BlocSuccessStories\" class=\"BlocBlanc\">\r\n    <div class=\"container TitreCentre\">\r\n      <h2>Projets r\u00e9alis\u00e9s avec des capteurs textiles<\/h2>\r\n      <div class=\"titre-underline\"><\/div>\r\n    <\/div>\r\n    <section id=\"BlocReal\">\r\n      <div class=\"relative\">\r\n        <nav class=\"list-real\" aria-label=\"R\u00e9alisations capteurs textiles AQ-Tech\" style=\"justify-content: center;\">\r\n\r\n          <!-- Optimergo -->\r\n          <a class=\"real-li\" href=\"\/fr\/realisations\/optimergo\/\">\r\n            <div class=\"real-img\">\r\n              <img loading=\"lazy\" decoding=\"async\"\r\n                src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Realisations\/Optimergo\/Optimergo-Vignette.webp\"\r\n                alt=\"Optimergo \u2014 V\u00eatement EMG pour analyse des TMS en industrie, AQ-Tech\">\r\n            <\/div>\r\n            <div class=\"bloc8-content-2024\">\r\n              <p class=\"bloc8-accueil-p-title\">Optimergo<\/p>\r\n              <p class=\"bloc8-accueil-p-content\">V\u00eatement EMG industrie<br>pr\u00e9vention des TMS<\/p>\r\n            <\/div>\r\n          <\/a>\r\n\r\n          <!-- T-Shirt Monitoring -->\r\n          <a class=\"real-li\" href=\"\/fr\/realisations\/t-shirt-monitoring\/\">\r\n            <div class=\"real-img\">\r\n              <img loading=\"lazy\" decoding=\"async\"\r\n                src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Realisations\/T-Shirt\/T-Shirt Vignette.webp\"\r\n                alt=\"T-Shirt Monitoring \u2014 Capteurs ECG et respiration int\u00e9gr\u00e9s, AQ-Tech\">\r\n            <\/div>\r\n            <div class=\"bloc8-content-2024\">\r\n              <p class=\"bloc8-accueil-p-title\">T-Shirt Monitoring<\/p>\r\n              <p class=\"bloc8-accueil-p-content\">Capteurs ECG &amp; respiration<br>monitoring sport &amp; m\u00e9dical<\/p>\r\n            <\/div>\r\n          <\/a>\r\n\r\n        <\/nav>\r\n      <\/div>\r\n    <\/section>\r\n    <div class=\"container TitreCentre\">\r\n      <div class=\"btn-orange liensection\" style=\"padding-bottom:60px;\">\r\n        <a href=\"\/fr\/realisations\/\">+ Voir toutes nos r\u00e9alisations<\/a>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- BLOC 5 : AUTRES PAGES FILLES ST -->\r\n  <div id=\"Bloc5Parcours\" class=\"MultiCol DeuxCol BlocNoir20 animate-slide-right\">\r\n    <div class=\"container\">\r\n      <div class=\"TitreCentre container\">\r\n        <h2>L&rsquo;expertise Smart Textile d&rsquo;AQ-Tech<\/h2>\r\n        <div class=\"titre-underline\"><\/div>\r\n        <h3>Les autres pages de notre p\u00f4le Smart Textile<\/h3>\r\n        <p>\r\n          Les capteurs textiles s&rsquo;int\u00e8grent dans une cha\u00eene de d\u00e9veloppement compl\u00e8te.\r\n          Une fois les donn\u00e9es mesur\u00e9es, elles doivent \u00eatre actionn\u00e9es, int\u00e9gr\u00e9es dans un produit\r\n          ou valid\u00e9es industriellement \u2014 des \u00e9tapes que nous ma\u00eetrisons toutes en interne.\r\n        <\/p>\r\n      <\/div>\r\n      <div class=\"list_carre_container\">\r\n        <div class=\"list_carre_article\">\r\n          <div class=\"image-carre\">\r\n            <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Actionneurs\/Actionneur-Integrable.webp\" alt=\"Actionneurs textiles AQ-Tech \u2014 haptique, EMS, chauffe int\u00e9gr\u00e9e\" \/>\r\n          <\/div>\r\n          <h3>Actionneurs textiles<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p>Int\u00e9gration de vibration haptique, EMS (\u00e9lectrostimulation), chauffe textile et lumineux dans vos v\u00eatements intelligents \u2014 pour fermer la boucle capteur \u2192 action.<\/p>\r\n          <div class=\"btn-orange liensection\">\r\n            <a href=\"\/fr\/poles\/smart-textile\/actionneurs-textiles-integres-vibration-lumiere-chauffe\/\">+ D\u00e9couvrir<\/a>\r\n          <\/div>\r\n        <\/div>\r\n        <div class=\"list_carre_article\">\r\n          <div class=\"image-carre\">\r\n            <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Poles\/SmartTextile\/Integration\/Integration-Textile-Electronique.webp\" alt=\"Int\u00e9gration produit Smart Textile AQ-Tech \u2014 architecture \u00e9lectronique et textile\" \/>\r\n          <\/div>\r\n          <h3>Int\u00e9gration produit Smart Textile<\/h3>\r\n          <div class=\"titre-underline\"><\/div>\r\n          <p>Du capteur au produit fini : architecture \u00e9lectronique, int\u00e9gration m\u00e9canique, firmware et tests fonctionnels pour un v\u00eatement connect\u00e9 pr\u00eat \u00e0 industrialiser.<\/p>\r\n          <div class=\"btn-orange liensection\">\r\n            <a href=\"\/fr\/poles\/smart-textile\/integration-produit-smart-textile\/\">+ En savoir plus<\/a>\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- BLOC 6 : CROSS-LINKS EXPERTISES & SECTEURS -->\r\n  <div id=\"Bloc6Cross\" class=\"MultiCol TroisCol animate-slide-right\">\r\n    <div class=\"container\">\r\n      <div class=\"TitreCentre container\">\r\n        <h2>Nos expertises au service de vos capteurs textiles<\/h2>\r\n        <div class=\"titre-underline\"><\/div>\r\n        <p>\r\n          Chez <strong>AQ-Tech<\/strong>, le d\u00e9veloppement de <strong>capteurs textiles int\u00e9gr\u00e9s<\/strong> repose sur la convergence de trois disciplines : <a href=\"\/fr\/expertises\/textile-technique\/\" class=\"lientexte\">textile technique<\/a> pour les mat\u00e9riaux conducteurs, les proc\u00e9d\u00e9s d&rsquo;int\u00e9gration et la lavabilit\u00e9 ; <a href=\"\/fr\/expertises\/electronique-logiciel\/\" class=\"lientexte\">\u00e9lectronique embarqu\u00e9e<\/a> pour l&rsquo;acquisition, le traitement du signal et la connectivit\u00e9 ; et <a href=\"\/fr\/expertises\/mecanique\/\" class=\"lientexte\">m\u00e9canique<\/a> pour la durabilit\u00e9 structurelle des connexions et la robustesse aux contraintes d&rsquo;usage.\r\n        <\/p>\r\n        <p>\r\n          Cette int\u00e9gration pluridisciplinaire nous permet de concevoir des capteurs textiles qui tiennent dans le temps \u2014 fiabilit\u00e9 du signal, tenue au lavage et industrialisabilit\u00e9. Nos applications couvrent le <a href=\"\/fr\/secteurs\/medical-bien-etre\/\" class=\"lientexte\">m\u00e9dical<\/a> (DM classe I et II, monitoring clinique), le <a href=\"\/fr\/secteurs\/sports-loisirs\/\" class=\"lientexte\">sport de performance<\/a> (analyse de geste, r\u00e9cup\u00e9ration, pr\u00e9vention blessures) et l&rsquo;<a href=\"\/fr\/secteurs\/industrie\/\" class=\"lientexte\">industrie<\/a> (TMS, ergonomie, EPI intelligent).\r\n        <\/p>\r\n        <p>\r\n          Le d\u00e9veloppement complet d&rsquo;un v\u00eatement connect\u00e9 \u2014 de la mesure \u00e0 l&rsquo;affichage de la donn\u00e9e \u2014 est assur\u00e9 par notre <a href=\"\/fr\/poles\/smart-textile\/\" class=\"lientexte\">p\u00f4le Smart Textile<\/a>, en coordination avec nos services de <a href=\"\/fr\/services\/prototypage-et-tests\/\" class=\"lientexte\">prototypage et validation<\/a> puis d&rsquo;<a href=\"\/fr\/services\/assemblage\/\" class=\"lientexte\">assemblage pr\u00e9-s\u00e9rie<\/a>. Pour les v\u00eatements connect\u00e9s complets, consulter notre page <a href=\"\/fr\/poles\/smart-textile\/developpement-vetement-connecte\/\" class=\"lientexte\">d\u00e9veloppement v\u00eatement connect\u00e9<\/a>.\r\n        <\/p>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- FAQ -->\r\n  <div id=\"Bloc7FAQ\" class=\"BlocGris20\">\r\n    <div class=\"container TitreCentre\">\r\n      <h2>Questions fr\u00e9quentes \u2014 Capteurs textiles int\u00e9gr\u00e9s<\/h2>\r\n      <div class=\"titre-underline\"><\/div>\r\n      <div class=\"faq-container\">\r\n        <div class=\"faq\">\r\n\r\n          <div class=\"faq_item\">\r\n            <h4 class=\"faq_question\">Quels types de capteurs pouvez-vous int\u00e9grer dans un textile ?<\/h4>\r\n            <p class=\"faq_reponse\">\r\n              \u00c9lectrodes ECG\/EMG, capteurs de respiration (thoracique et abdominale), mesure de temp\u00e9rature cutan\u00e9e, IMU (acc\u00e9l\u00e9rom\u00e8tre, gyroscope, magn\u00e9tom\u00e8tre), capteurs de flexion\/\u00e9longation, vibration et impact, pression musculaire, hydratation et conduction cutan\u00e9e (GSR\/EDA). Chaque type implique des mat\u00e9riaux, des proc\u00e9d\u00e9s d&rsquo;int\u00e9gration et une architecture \u00e9lectronique sp\u00e9cifiques \u2014 nous \u00e9tablissons un cadrage technique avec vous d\u00e8s le d\u00e9marrage.\r\n            <\/p>\r\n          <\/div>\r\n\r\n          <div class=\"faq_item\">\r\n            <h4 class=\"faq_question\">Vos capteurs textiles sont-ils lavables ?<\/h4>\r\n            <p class=\"faq_reponse\">\r\n              Oui. La lavabilit\u00e9 est une contrainte int\u00e9gr\u00e9e d\u00e8s la phase de conception \u2014 s\u00e9lection des mat\u00e9riaux conducteurs, techniques d&rsquo;encapsulation (surmoulage silicone, laminage \u00e9tanche) et protocoles de connectique textile. Nous validons chaque architecture avec des cycles de lavage r\u00e9p\u00e9t\u00e9s (norme ISO 6330 ou \u00e9quivalent). Les r\u00e9sultats \u2014 r\u00e9sistance du signal avant\/apr\u00e8s lavage, int\u00e9grit\u00e9 m\u00e9canique \u2014 font partie du dossier de validation.\r\n            <\/p>\r\n          <\/div>\r\n\r\n          <div class=\"faq_item\">\r\n            <h4 class=\"faq_question\">D\u00e9veloppez-vous l&rsquo;\u00e9lectronique associ\u00e9e aux capteurs ?<\/h4>\r\n            <p class=\"faq_reponse\">\r\n              Oui, c&rsquo;est l&rsquo;un de nos diff\u00e9renciants. Nous d\u00e9veloppons les modules d&rsquo;acquisition (AFE, ADC haute pr\u00e9cision), le firmware embarqu\u00e9, le traitement du signal et la connectivit\u00e9 (BLE, ANT+, propri\u00e9taire). L&rsquo;ing\u00e9nieur textile et l&rsquo;ing\u00e9nieur \u00e9lectronique travaillent ensemble d\u00e8s le d\u00e9but \u2014 contraintes de placement, c\u00e2blage et int\u00e9gration m\u00e9canique sont r\u00e9solus en m\u00eame temps que les performances de mesure.\r\n            <\/p>\r\n          <\/div>\r\n\r\n          <div class=\"faq_item\">\r\n            <h4 class=\"faq_question\">Peut-on mesurer plusieurs signaux sur un m\u00eame v\u00eatement ?<\/h4>\r\n            <p class=\"faq_reponse\">\r\n              Absolument. Nous r\u00e9alisons des architectures multi-capteurs synchronis\u00e9es : ECG + IMU + respiration + temp\u00e9rature sur un m\u00eame v\u00eatement, avec des canaux d&rsquo;acquisition ind\u00e9pendants. La synchronisation temporelle des signaux est g\u00e9r\u00e9e par firmware. Ce type d&rsquo;architecture est utilis\u00e9 notamment en monitoring sportif et en dispositifs m\u00e9dicaux wearables.\r\n            <\/p>\r\n          <\/div>\r\n\r\n          <div class=\"faq_item\">\r\n            <h4 class=\"faq_question\">Quelle pr\u00e9cision atteignent vos capteurs textiles ECG ou EMG ?<\/h4>\r\n            <p class=\"faq_reponse\">\r\n              La pr\u00e9cision d\u00e9pend de l&rsquo;application, du positionnement des \u00e9lectrodes et des conditions d&rsquo;usage (mouvement, transpiration, pression de contact). En conditions contr\u00f4l\u00e9es, nos \u00e9lectrodes textiles ECG atteignent une qualit\u00e9 de signal comparable aux dispositifs de r\u00e9f\u00e9rence. Pour les applications m\u00e9dicales classe II, nous accompagnons les tests de validation clinique et la constitution du dossier technique MDR.\r\n            <\/p>\r\n          <\/div>\r\n\r\n          <div class=\"faq_item\">\r\n            <h4 class=\"faq_question\">Quels sont les d\u00e9lais typiques pour d\u00e9velopper un capteur textile ?<\/h4>\r\n            <p class=\"faq_reponse\">\r\n              Pour un premier prototype fonctionnel : 4 \u00e0 8 semaines selon la complexit\u00e9 (type de capteur, contraintes de lavabilit\u00e9, module \u00e9lectronique associ\u00e9). Pour une architecture multi-capteurs valid\u00e9e avec firmware : 3 \u00e0 4 mois. La pr\u00e9-s\u00e9rie industrielle (50 \u00e0 200 unit\u00e9s avec dossier qualit\u00e9) demande g\u00e9n\u00e9ralement 5 \u00e0 7 mois au total. Ces d\u00e9lais d\u00e9pendent fortement de la maturit\u00e9 du cahier des charges \u2014 nous vous aidons \u00e0 le structurer d\u00e8s le premier \u00e9change.\r\n            <\/p>\r\n          <\/div>\r\n\r\n          <div class=\"faq_item\">\r\n            <h4 class=\"faq_question\">Prenez-vous en charge les certifications m\u00e9dicales ou EPI ?<\/h4>\r\n            <p class=\"faq_reponse\">\r\n              Pour les dispositifs m\u00e9dicaux, nous vous accompagnons dans la pr\u00e9paration du dossier technique MDR (EU 2017\/745), les tests de biocompatibilit\u00e9 (ISO 10993) et la validation clinique. Pour les EPI avec capteurs int\u00e9gr\u00e9s, nous g\u00e9rons les exigences CE EPI (r\u00e8glement EU 2016\/425). Dans les deux cas, ces contraintes sont anticip\u00e9es d\u00e8s la conception pour \u00e9viter les reprises co\u00fbteuses en fin de d\u00e9veloppement.\r\n            <\/p>\r\n          <\/div>\r\n\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <!-- CTA FINAL -->\r\n  <div id=\"BlocCTA\" class=\"ImageTexte TroisQuart\">\r\n    <div class=\"container relative\">\r\n      <img loading=\"lazy\" decoding=\"async\" class=\"absolute\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/All\/Fleche-Haut.webp\" \/>\r\n      <div class=\"ImageTexteBlocImgContainer\">\r\n        <img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/themes\/ThemeAQTech2025-2\/_MediaTheme2025\/Image\/Contact\/LienContact.webp\" alt=\"Contact AQ-Tech \u2014 capteurs textiles sur mesure\" \/>\r\n      <\/div>\r\n      <div id=\"Bloc2AccueilTextContainer\" class=\"ImageTexteBlocTextContainer animate-slide-right\">\r\n        <h2>D\u00e9veloppons ensemble vos capteurs textiles.<\/h2>\r\n        <div class=\"titre-underline\"><\/div>\r\n        <p>\r\n          AQ-Tech con\u00e7oit, int\u00e8gre et industrialise vos <strong>capteurs textiles<\/strong> pour le sport, le m\u00e9dical, l&rsquo;industrie ou les dispositifs professionnels \u2014 avec le module \u00e9lectronique, le firmware et la validation lavabilit\u00e9. R\u00e9ponse sous 48h.\r\n        <\/p>\r\n        <div class=\"btn-orange\">\r\n          <a href=\"\/fr\/contact\/\">+ Nous contacter<\/a>\r\n        <\/div>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n\r\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Capteurs Textiles Int\u00e9gr\u00e9s ECG, EMG, IMU &amp; Mesure Physiologique dans le V\u00eatement Accueil \u203a P\u00f4le Smart Textile \u203a Capteurs Textiles Int\u00e9gr\u00e9s Des architectures de capteurs textiles robustes, pr\u00e9cises et industrialisables. Les capteurs rigides ont leurs limites d\u00e8s qu&rsquo;il s&rsquo;agit de mesurer le corps en mouvement. AQ-Tech con\u00e7oit des capteurs textiles int\u00e9gr\u00e9s capables de mesurer des [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":6488,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6771","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Capteurs Textiles Int\u00e9gr\u00e9s \u2014 ECG, EMG &amp; IMU | AQ-Tech<\/title>\n<meta name=\"description\" content=\"AQ-Tech int\u00e8gre des capteurs textiles fiables : \u00e9lectrodes ECG\/EMG, IMU, respiration, temp\u00e9rature et flexion. Du prototype \u00e0 la pr\u00e9-s\u00e9rie industrielle.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Capteurs Textiles Int\u00e9gr\u00e9s \u2014 ECG, EMG &amp; IMU | AQ-Tech\" \/>\n<meta property=\"og:description\" content=\"AQ-Tech int\u00e8gre des capteurs textiles fiables : \u00e9lectrodes ECG\/EMG, IMU, respiration, temp\u00e9rature et flexion. Du prototype \u00e0 la pr\u00e9-s\u00e9rie industrielle.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/\" \/>\n<meta property=\"og:site_name\" content=\"AQ-Tech\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-21T05:37:05+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/\",\"url\":\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/\",\"name\":\"Capteurs Textiles Int\u00e9gr\u00e9s \u2014 ECG, EMG & IMU | AQ-Tech\",\"isPartOf\":{\"@id\":\"https:\/\/www.aq-tech.fr\/fr\/#website\"},\"datePublished\":\"2025-11-19T12:02:52+00:00\",\"dateModified\":\"2026-03-21T05:37:05+00:00\",\"description\":\"AQ-Tech int\u00e8gre des capteurs textiles fiables : \u00e9lectrodes ECG\/EMG, IMU, respiration, temp\u00e9rature et flexion. Du prototype \u00e0 la pr\u00e9-s\u00e9rie industrielle.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.aq-tech.fr\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Poles\",\"item\":\"https:\/\/www.aq-tech.fr\/fr\/poles\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Smart-Textile\",\"item\":\"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Capteurs textiles int\u00e9gr\u00e9s\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.aq-tech.fr\/fr\/#website\",\"url\":\"https:\/\/www.aq-tech.fr\/fr\/\",\"name\":\"AQ-Tech\",\"description\":\"Bureau d&#039;Etude d&#039;Ing\u00e9nierie M\u00e9canique &amp; Electronique &amp; industrielle\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.aq-tech.fr\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Capteurs Textiles Int\u00e9gr\u00e9s \u2014 ECG, EMG & IMU | AQ-Tech","description":"AQ-Tech int\u00e8gre des capteurs textiles fiables : \u00e9lectrodes ECG\/EMG, IMU, respiration, temp\u00e9rature et flexion. Du prototype \u00e0 la pr\u00e9-s\u00e9rie industrielle.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/","og_locale":"fr_FR","og_type":"article","og_title":"Capteurs Textiles Int\u00e9gr\u00e9s \u2014 ECG, EMG & IMU | AQ-Tech","og_description":"AQ-Tech int\u00e8gre des capteurs textiles fiables : \u00e9lectrodes ECG\/EMG, IMU, respiration, temp\u00e9rature et flexion. Du prototype \u00e0 la pr\u00e9-s\u00e9rie industrielle.","og_url":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/","og_site_name":"AQ-Tech","article_modified_time":"2026-03-21T05:37:05+00:00","twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/","url":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/","name":"Capteurs Textiles Int\u00e9gr\u00e9s \u2014 ECG, EMG & IMU | AQ-Tech","isPartOf":{"@id":"https:\/\/www.aq-tech.fr\/fr\/#website"},"datePublished":"2025-11-19T12:02:52+00:00","dateModified":"2026-03-21T05:37:05+00:00","description":"AQ-Tech int\u00e8gre des capteurs textiles fiables : \u00e9lectrodes ECG\/EMG, IMU, respiration, temp\u00e9rature et flexion. Du prototype \u00e0 la pr\u00e9-s\u00e9rie industrielle.","breadcrumb":{"@id":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/capteurs-textiles-integres\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.aq-tech.fr\/fr\/"},{"@type":"ListItem","position":2,"name":"Poles","item":"https:\/\/www.aq-tech.fr\/fr\/poles\/"},{"@type":"ListItem","position":3,"name":"Smart-Textile","item":"https:\/\/www.aq-tech.fr\/fr\/poles\/smart-textile\/"},{"@type":"ListItem","position":4,"name":"Capteurs textiles int\u00e9gr\u00e9s"}]},{"@type":"WebSite","@id":"https:\/\/www.aq-tech.fr\/fr\/#website","url":"https:\/\/www.aq-tech.fr\/fr\/","name":"AQ-Tech","description":"Bureau d&#039;Etude d&#039;Ing\u00e9nierie M\u00e9canique &amp; Electronique &amp; industrielle","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aq-tech.fr\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/pages\/6771","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/comments?post=6771"}],"version-history":[{"count":20,"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/pages\/6771\/revisions"}],"predecessor-version":[{"id":6982,"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/pages\/6771\/revisions\/6982"}],"up":[{"embeddable":true,"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/pages\/6488"}],"wp:attachment":[{"href":"https:\/\/www.aq-tech.fr\/fr\/wp-json\/wp\/v2\/media?parent=6771"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}